Scenario 5 Set Output Relays
Select Detector Interface and Route Relays:
1) Click the Detector Interface button to select the
type of detector/controller interface to be used (
BIU #1 Card File ).
2) Click the Ph- button to select Phase group 3L.
Note that the line zones corresponding to the
selected phase group turn green. All others are
magenta.
3) Click the RI/Card= button to select the number
of relays per card = 2 . Click the RI Slot= to select
the card file slot used= 2.
4) After selecting the RI/Card=2 and the RI Slot=2,
the number detector channels (D1, D2, etc.) that
are shown changes corresponding to this selection.
5) Click the Ext= and the Dly= to select the
Detection Extension in seconds and the Detection
Delay in seconds.
6) Click N, Or, And button to select logic for
combining (N=Not Used) Phase Groups into
Detector Channels.
7) To clear the settings for the selected Phase
group or for all Phase groups click the Clear or the
Clear All button.
1
2
3
4
7
5
BIU #1 Card file Detector/Controller Interface with 2 Relays per SVS-1 card, Slot 2 used, and 3 Phases (Line Zone Groups)
Phase 3L, Detection Delay=0 sec, Detection Extension=0, Route to Detector Channel D1
Phase 8T, Detection Delay=0 sec, Detection Extension=0, Route to Detector Channel D2
Phase 8R, Detection Delay=2 sec, Detection Extension=2, Route to Detector Channel D2
6
Specifies Routing to Onboard Output Relay
Connector (1, 2, .., 10 0-Disables) for shelf
mount SVS-1
Vue de la page 24